Price for 6000 Blackwell series cards have stabilized after 3 consecutive 30% baseline hikes by Nvidia in 2026 and are expected to maintain through the rest of 2026. Supply remains strained. Please note that compliance is mandatory on all AI enterprise compute GPUs and Servers and end-user forms must be filled out before we can share any quotes. Please note Credit Card payments will only work if USD or AED currency is selected on top right corner of the website. HGX B200/B300 lead times are now between 8-14 weeks for Golden Sku, with custom BOMs exceed 20 weeks. For DRAM and SSD bulk orders, please inquire in the chat.
Please download our ModuleBox V4 brochure in the “Downloads” tab for detailed information and specifications. 1 year parts warranty included from date of delivery.
30 day production time plus ocean freight transit. Will provide reduced invoice for customs clearance. Door-to-Door shipping available (ranges between $4,000 USD – $12,000 USD depending on model selection and final destination of delivery). Crane required on-site for container placement.
Verified reviews from real customers on Trustpilot



| Specification | Module Box-20HC | Module Box-40HC |
|---|---|---|
| External Sizes (mm) | 6058 × 2438 × 2896 | 12192 × 2438 × 2896 |
| Internal Sizes (mm) | 5900 × 1380 × 2600 | 11800 × 1380 × 2600 |
| Weight | 4T (±5%) | 8T (±5%) |
| Overall Volume (m³) | 42.77 | 86.08 |
| Shelf System | ||
| Internal Shelf Layers | 2 × 6 | 4 × 6 |
| Maximum Miners | 210 | 420 |
| Miner Model | S19Pro or others | S19Pro or others |
| Shelf Height (mm) | 400 | 400 |
| Adjustable Shelf Hole Distance (mm) | 40 | 40 |
| Power Supply System | ||
| Input Voltage | 360 V – 480 V | 360 V – 480 V |
| Module Output | 200 V – 277 V, 50–60 Hz | 200 V – 277 V, 50–60 Hz |
| Maximum Total Power | 830 kW/h (3780 A) | 1500 kW/h (6250 A) |
| PDU Power | 3696 W/h (20 A) | 3696 W/h (20 A) |
| Custom Switch | 200 V – 280 V | 200 V – 280 V |
| Intelligent PDU | 200 V – 280 V | 200 V – 280 V |
| Intelligent Server | 200 V – 280 V | 200 V – 280 V |
| Multi-Level Security Protection | ||
| Class 1 – Leakage Protector | Yes | Yes |
| Class 2 – Fuse Protector | Yes | Yes |
| Class 3 – Breaker Control Switch | Yes | Yes |
| Class 4 – PDU Independent Power Outage | Yes | Yes |
| Input Mode | 3-Phase Equilibrium | 3-Phase Equilibrium |
| Cooling System | ||
| Cooling Mode | Water Cooling Curtain, Miner Fan Heat Dissipation | Water Cooling Curtain, Miner Fan Heat Dissipation |
| Water Supply Pressure | ≤ 1.5 Pa | ≤ 1.5 Pa |
| Cold and Heat Isolation Panel | Waterproof, Flame-Retarded | Waterproof, Flame-Retarded |
| Dust Screen | Reduce Attachments | Reduce Attachments |
| Louver | Rainproof | Rainproof |
| Other Details | ||
| Intelligent Control System | The first inclusive network-based background interaction system | The first inclusive network-based background interaction system |
| Fire Fighting System | Smoke Detector | Smoke Detector |
| Temperature & Humidity Monitoring | Temperature & Humidity Sensor | Temperature & Humidity Sensor |
| Operating Conditions | ||
| Applicable Environments | For both indoor and outdoor uses | For both indoor and outdoor uses |
No file available